Journal of
Faculty of Civil Engineering


JOURNALS
FACULTY JOURNALS
SCIENTIFIC MEETINGS
EBOOKS
ARCHIVE








CONFERENCE PROCEEDINGS INTERNATIONAL CONFERENCE
"CONTEMPORARY ACHIEVEMENTS IN CIVIL ENGINEERING 2015 "
FACULTY OF CIVIL ENGINEERING SUBOTICA , 2015.y., pp. 81-86


HYGROTHERMAL PERFORMANCE OF BUILDING IN RELATION TO THE CLIMATIC PARAMETERS
 
DOI: 10.14415/konferencijaGFS 2015.009
UDC: 628.853:624.04
CC-BY-SA 4.0 license
Author : Sinđić-Grebović, Radmila
 
 Summary:
 Transport of moisture through the elements of the cover can be analyzed using different methods, by adopting various climatic parameters, which can significantly influence reliability of results. This paper shows results of the calculations of interstitial condensation as a function of the adopted climatic elements. Glaser method is used for the calculation – despite being approximate it is still most widely recognized. It is concluded that the validity of calculations requires well defined national stipulations on climatic parameters.
 
 Keywords:
 water vapour diffusion,interstitial condensation, climatic parameters