JOURNAL OF FACULTY OF CIVIL ENGINEERINGINTERNATIONAL CONFERENCECONTEMPORARY ACHIEVEMENTS IN CIVILENGINEERING 25, 2014.y., pp. 653-659
PARSHALL FLUME CALIBRATION FOR FREE FLOW |
 |
DOI: 10.14415/konferencijaGFS2014.087 |
UDC: 532.51 |
CC-BY-SA 4.0 license |
Author : Hovány, Lajos; Gabrić, Ognjen |
|
| Summary: |
| For a b=0.0254m wide Parshall flume, the literature provides the dependence of flowrate and water depth in the throat within the flowrate range of Qmin-Qmax – discharge curve. The calibration of discharge curve by transposing measuring point 1 to measuring point 2, error values were obtained, which are lower than the ones recommended by the standards of this country and the relevant literature. A new discharge curve was set for flowrate below Qmin at measuring point 2 and at water temperature of 16 to 17oC. |
|
| Keywords: |
| Calibration, Parshall flume, free flow, viscosity of water |
|
|
|