CONFERENCE PROCEEDINGS INTERNATIONAL CONFERENCE"CONTEMPORARY ACHIEVEMENTS IN CIVIL ENGINEERING 2015 "FACULTY OF CIVIL ENGINEERING SUBOTICA , 2015.y., pp. 583-588
PARSHALL FLUME CALIBRATION FOR HYDROGRAPH MEASUREMENT | |
 |
| DOI: 10.14415/konferencijaGFS 2015.072 |
| UDC: 532.57 |
| CC-BY-SA 4.0 license |
| Author : Gabrić, Ognjen; Hovány, Lajos; Horvat, Mirjana; Horvat, Zoltan |
| |
| | Summary: |
| | For a b=0.0254 m wide Parshall flume, literature provides the dependence
of flowrate and water depth in the throat within the flowrate range of 0.13-4.38 l/s. Volumetric measurements of flow (flow range 0 – 3 l/s) and water level measurements with ultrasonic transmitter prove that hydrograph can be determined using equation (2) (within accuracy range of -5.36 to +4.99%), or with equations (4) and (5) (within accuracy range of -3.46 to +4.77%) for water temperatures of 11.5-16oC.
|
| |
| | Keywords: |
| | accuracy, calibration, Parshall flume, free flow, ultrasonic transmitter |
| |
| |
| |