Author : Obradović, Nikola; Marjanović, Miloš; Pujević, Veljko; Vukićević, Mirjana
 
 Summary:
 Short review of provisions of Eurocode 7 for determination of pile axial bearing capacity is given in this paper. Design guidelines and recommendations for determination of bearing capacity of jacked-in MEGA piles, according to pile installation technology and chosen design approach in National Annex for Eurocode 7 (Part 1) in Serbia are presented. A validation of proposed guidelines through comparison with previous concept of allowable pile force is presented on the example of the rehabilitation of the foundations of a residential building in Zemun, Serbia. Obtained results confirm the adequacy of chosen design approach and proposed guidelines for determination of bearing capacity of MEGA piles.
 
 Keywords:
 Eurocode 7, MEGA pile, bearing capacity, foundation repair.