Journal of
Faculty of Civil Engineering


JOURNALS
FACULTY JOURNALS
SCIENTIFIC MEETINGS
EBOOKS
ARCHIVE








JOURNAL OF FACULTY OF CIVIL ENGINEERING 30, 2016.y., pp. 63-72


CALCULATION OF DEFLECTION FOR CROSS LAMINATED TIMBER FLOOR PANEL
 
DOI: 10.14415/zbornikGFS30.06
UDC: 692.5 : 691.116
CC-BY-SA 4.0 license
Author : Kozarić, Ljiljana M.; Prokić, Aleksandar; Bešević, Miroslav; Vojnić Purčar, Martina
 
 Summary:
 In this paper analytically calculated values of effective flexural stiffness and deflections of five-layer CLT panels height 14 cm due to the payload defined in Eurocode 1 for floors in residential buildings are compared. Effective flexural stiffness was calculated using Gamma method, K-method and Kreuzinger's analogy. Three floor panels with identical height but with different combinations of lamination thicknesses in crosslayers were analyzed. The panels are 4.5 meters long and 1 meter wide. Lamination thicknesses in cross-sections of panels are 33,4 cm+21,9 cm, then 33 cm+22,5 cm and 52,8 cm.
 
 Keywords:
 cross laminated timber, floor construction, deflections